160.077-21—Approval Testing—Type I and Commercial Hybrid PFD.
(a) General.
This section contains commercial hybrid PFD approval tests. The provisions of § 160.077-19(a) apply to each test in this section.
(b) Tests.
Each test prescribed in § 160.077-19(b), except the tests in paragraphs (b)(2), (b)(3)(i), (b)(3)(ii), and (b)(6), must be conducted and passed.
(c) Additional tests.
Each PFD design must also be tested according to the procedures in the following tests and meet the requirements in these tests:
(1)
Jump test, UL 1517, section S6 for Adult size. Youth and Small Child sizes are exempt from this test.
(2)
In-water removal, UL 1517, section S9 for Adult and Youth sizes. The Small Child size is exempt from this test.
(3)
Buoyancy and inflation medium retention test, UL 1517, Section S10, except the minimum buoyancies must be as specified in the Table 160.077-17(b)(11):
(i)
Uninflated flotation stability, UL 1517, section S7, except that for Type I devices the requirements of paragraph S7.1.A apply to all subjects regardless of their in-water weight. For Type V adult-size devices the requirements of paragraph S7.1.A apply to all adult subjects having an in-water weight of 13 lb or less, and the requirements of paragraph S7.1.B apply to all other adult subjects.
Code of Federal Regulations
(ii)
Righting action test, 46 CFR 160.176-13(d)(2) through (d)(5) for Type I hybrid PFDs. UL 1517, Section S8, for Type V hybrid PFDs.
(i)
Uninflated flotation stability, UL 1517, section S7, except that the requirements of paragraph S7.1.A apply to all subjects regardless of their in-water weight.
(ii)
Righting action test, UL 1517, Section 15.3 through 15.13, for Youth and Small Child hybrid PFDs except comparisons are to be made to the appropriate size and type reference vest as defined in § 160.077-2(j).
(1)
At least 75% of the PFD's retroreflective material on the outside of the PFD, and the PFD light, must be above the water when the subject is floating in the stable flotation attitude; and
(2)
The subject when floating in the stable flotation position and looking to the side, must be able to see—
(ii)
A mark on a vertical scale no higher than the lowest mark which can be viewed when floating in the same position in the reference vest defined in § 160.077-3(j).
(e) Visual Examination.
One complete PFD must be visually examined for compliance with the requirements of § 160.077-15 and § 160.077-17.
(f) Inflation Chamber Properties.
If the tests in paragraphs (b) and (c) of this section are completed successfully, the tests in § 160.077-19(d) must be run.
(g)
The Commandant may prescribe additional tests, if necessary, to approve unique or novel designs.
[CGD 78-174, 50 FR 33928, Aug. 22, 1985, as amended by CGD 78-174, 60 FR 2488, Jan. 9, 1995; 60 FR 7131, Feb. 7, 1995; CGD 95-072, 60 FR 50466, Sept. 29, 1995]