572.73—Neck assembly and test procedure.

Table B
Rotation (degrees) Time (ms) ±(2 .08T) Chordal displacement (inches) ±0.8
0 0 0
30 26 2.7
60 44 4.3
Maximum 68 5.8
60 101 4.4
30 121 2.4
0 140 0
(1) Mount the head and neck assembly on a rigid pendulum as specified in § 572.21, Figure 15, so that the head's midsagittal plane is vertical and coincides with the plane of motion of the pendulum's longitudinal center line. Attach the neck directly to the pendulum as shown in § 572.21, Figure 15.
[56 FR 57836, Nov. 14, 1991, as amended at 57 FR 4086, Feb. 3, 1992]