178.61—Specification 4BW welded steel cylinders with electric-arc welded longitudinal seam.

Code of Federal Regulations

S = [2P(1.3D2 0.4d2)] / [E(D2 − d2)]
where:
S = wall stress, psi;
P = service pressure, psig;
D = outside diameter, inches;
d = inside diameter, inches;
E = joint efficiency of the longitudinal seam (from paragraph (d) of this section).
(p) Inspector's report. In addition to the information required by § 178.35, the inspector's report must indicate the type and amount of radiography.
[Amdt. 178-114, 61 FR 25942, May 23, 1996, as amended at 64 FR 51919, Sept. 27, 1999; 66 FR 45386, 45388, Aug. 28, 2001; 67 FR 51654, Aug. 6, 2002; 67 FR 61016, Sept. 27, 2002; 68 FR 57633, Oct. 6, 2003; 68 FR 75748, Dec. 31, 2003]