178.45—Specification 3T seamless steel cylinder.

Analysis Tolerances
Element Ladle analysis Check Analysis
Under Over
Carbon 0.35 to 0.50 0.03 0.04
Manganese 0.75 to 1.05 0.04 0.04
Phosphorus (max) 0.035 0.01
Sulphur (max) 0.04 0.01
Silicon 0.15 to 0.35 0.02 0.03
Chromium 0.80 to 1.15 0.05 0.05
Molybdenum 0.15 to 0.25 0.02 0.02

Code of Federal Regulations

S = [P(1.3D2 0.4d2)] / (D2 − d2)
Where:
S = Wall stress in psi;
P = Minimum test pressure, at least 5/3 service pressure;
D = Outside diameter in inches;
d = Inside diameter in inches.
S = Mc / I
Where:
S = Tensile stress in psi;
M = Bending moment in inch-pounds (wl2/8);
I = Moment of inertia—0.04909 (D4−d4) in inches fourth;
c = Radius (D/2) of cylinder in inches;
w = Weight per inch of cylinder filled with water;
l = Length of cylinder in inches;
D = Outside diameter in inches;
d = Inside diameter in inches.

Code of Federal Regulations

S = A1 P / A2
Where:
S = Tensile stress in psi;
A1 = Internal area in cross section of cylinder in square inches;
P = Hydrostatic test pressure-psig;
A2 = Area of metal in cross section of cylinder in square inches.
Size of specimen (mm) Average value for acceptance (3 specimens) Minimum value (1 specimen only of the 3)
10.0×10.0 25.0 ft. lbs. 20.0 ft. lbs.
10.0×7.5 21.0 ft. lbs. 17.0 ft. lbs.
10.0×5.0 17.0 ft. lbs. 14.0 ft. lbs.
(n) Inspector's report. In addition to the requirements of § 178.35, the inspector's report for the physical test report, must indicate the average value for three specimens and the minimum value for one specimen for each lot number.
[Amdt. 178-114, 61 FR 25942, May 23, 1996, as amended at 66 FR 45385, 43588, Aug. 28, 2001; 67 FR 51652, Aug. 8, 2002; 68 FR 48571, Aug. 14, 2003; 68 FR 75748, 75749, Dec. 31, 2003]