178.37—Specification 3AA and 3AAX seamless steel cylinders.

S = Mc/I

Code of Federal Regulations

S = A1P/A2
Where:
S = tensile stress-p.s.i.;
M = bending moment-inch pounds (wl2)/8;
w = weight per inch of cylinder filled with water;
l = length of cylinder-inches;
c = radius (D)/(2) of cylinder-inches;
I = moment of inertia-0.04909 (D4−d4) inches fourth;
D = outside diameter-inches;
d = inside diameter-inches;
A1 = internal area in cross section of cylinder-square inches;
A2 = area of metal in cross section of cylinder-square inches;
P = hydrostatic test pressure-psig.
Table 1—Authorized Materials
Designation 4130X (percent) (see Note 1) NE-8630 (percent) (see Note 1) 9115 (percent) (see Note 1) 9125 (percent) (see Note 1) Carbon-boron (percent) Inter- mediate manganese (percent)
Carbon 0.25/0.35 0.28/0.33 0.10/0.20 0.20/0.30 0.27-0.37 0.40 max.
Manganese 0.40/0.90 0.70/0.90 0.50/0.75 0.50/0.75 0.80-1.40 1.35/1.65.
Phosphorus 0.04 max 0.04 max 0.04 max 0.04 max 0.035 max 0.04 max.
Sulfur 0.05 max 0.04 max 0.04 max 0.04 max 0.045 max 0.05 max.
Silicon 0.15/0.35 0.20/0.35 0.60/0.90 0.60/0.90 0.3 max. 0.10/0.30.
Chromium 0.80/1.10 0.40/0.60 0.50/0.65 0.50/0.65.
Molybdenum 0.15/0.25 0.15/0.25
Zirconium 0.05/0.15 0.05/0.15
Nickel 0.40/0.70
Boron 0.0005/0.003.
Note 1: This designation may not be restrictive and the commercial steel is limited in analysis as shown in this table.
Table 2—Check Analysis Tolerances
Element Limit or maximum specified(percent) Tolerance (percent) over the maximum limit or under the minimum limit
Under minimum limit Over maximum limit
Carbon To 0.15 incl 0.02 0.03
Over 0.15 to 0.40 incl .03 .04
Manganese To 0.60 incl .03 .03
Over 0.60 to 1.15 incl 0.04 0.04
Over 1.15 to 2.50 incl 0.05 0.05
Phosphorus1 All ranges .01
Sulphur All ranges .01
Silicon To 0.30 incl .02 .03
Over 0.30 to 1.00 incl .05 .05
Nickel To 1.00 incl .03 .03
Chromium To 0.90 incl .03 .03
0.90 to 2.90 incl .05 .05
Molybdenum To 0.20 incl .01 .01
Over 0.20 to 0.40 .02 .02
Zirconium All ranges .01 .05
1 Rephosphorized steels not subject to check analysis for phosphorus.

Code of Federal Regulations

S = [P(1.3D2 0.4d2)]/(D2−d2)
Where:
S = wall stress in psi;
P = minimum test pressure prescribed for water jacket test or 450 psig whichever is the greater;
D = outside diameter in inches;
d = inside diameter in inches.
[Amdt. 178-114, 61 FR 25942, May 23, 1996, as amended at 65 FR 58631, Sept. 29, 2000; 66 FR 45386-45387, Aug. 28, 2001; 67 FR 51652, Aug. 8, 2002; 68 FR 75748, Dec. 31, 2003]