178.345-10—Pressure relief.

Table I—Minimum Emergency Vent Capacity
[In cubic feet free air/hour at 60 °F and 1 atm.]
Exposed area in square feet Cubic feet free air per hour
20 15,800
30 23,700
40 31,600
50 39,500
60 47,400
70 55,300
80 63,300
90 71,200
100 79,100
120 94,900
140 110,700
160 126,500
180 142,300
200 158,100
225 191,300
250 203,100
275 214,300
300 225,100
350 245,700
400 265,000
450 283,200
500 300,600
550 317,300
600 333,300
650 348,800
700 363,700
750 378,200
800 392,200
850 405,900
900 419,300
950 432,300
1,000 445,000
Note 1: Interpolate for intermediate sizes.
[Amdt. 178-89, 54 FR 25025, June 12, 1989, as amended at 55 FR 21038, May 22, 1990; 55 FR 37062, Sept. 7, 1990; Amdt. 178-89, 56 FR 27877, June 17, 1991; Amdt. 178-105, 59 FR 55175, Nov. 3, 1994; Amdt. 178-118, 61 FR 51341, Oct. 1, 1996; 65 FR 58631, Sept. 29, 2000; 66 FR 45389, Aug. 28, 2001; 68 FR 19284, Apr. 18, 2003]