405.92—Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 3.450 1.380
TSS 5.175 2.070
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.345 0.138
TSS 0.518 .207
pH (1) (1)
1 Within the range 6.0 to 9.0.
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 4.60 2.30
TSS 6.90 .450
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.460 0.230
TSS 0.690 .345
pH (1) (1)
1 Within the range 6.0 to 9.0.
[39 FR 18597, May 28, 1974, as amended at 39 FR 32993, Sept. 13, 1974; 60 FR 33935, June 29, 1995]