405.12—Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 0.475 0.190
TSS 0.713 .285
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.048 0.019
TSS 0.071 .029
pH (1) (1)
1 Within the range 6.0 to 9.0.
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 0.625 0.313
TSS 0.938 .469
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.063 0.031
TSS 0.094 .047
pH (1) (1)
1 Within the range 6.0 to 9.0.
[39 FR 18597, May 28, 1974, as amended at 60 FR 33933, June 29, 1995]