305.8—Submission of data.

(a) (1) Each manufacturer of a covered product (except manufacturers of fluorescent lamp ballasts, metal halide lamp fixtures, showerheads, faucets, water closets, urinals, general service fluorescent lamps, and general service lamps) shall submit annually to the Commission a report listing the estimated annual energy consumption (for refrigerators, refrigerator-freezers, freezers, clothes washers, dishwashers, and water heaters) or the energy efficiency rating (for room air conditioners, central air conditioners, heat pumps, furnaces, ceiling fans, and pool heaters) for each basic model in current production, determined according to § 305.5 and statistically verified according to § 305.6. The report must also list, for each basic model in current production: the brand name; the model numbers for each basic model; the total energy consumption, determined in accordance with § 305.5, used to calculate the estimated annual energy consumption or energy efficiency rating; the number of tests performed; and, its capacity, determined in accordance with § 305.7. For those models that use more than one energy source or more than one cycle, each separate amount of energy consumption, measured in accordance with § 305.5, shall be listed in the report. Starting serial numbers or other numbers identifying the date of manufacture of covered products shall be submitted whenever a new basic model is introduced on the market. For ceiling fans, the report shall contain the fan diameter in inches and also shall contain efficiency ratings, energy consumption, and capacity at high speed.
(2) Each manufacturer of a covered fluorescent lamp ballast shall submit annually to the Commission a report for each basic model of fluorescent lamp ballast in current production. The report shall contain the following information:
(i) Name and address of manufacturer;
(ii) All trade names under which the fluorescent lamp ballast is marketed;
(iii) Model number;
(iv) Starting serial number, date code or other means of identifying the date of manufacture (date of manufacture information must be included with only the first submission for each basic model);
(v) Nominal input voltage and frequency;
(vi) Ballast efficacy factor; and
(vii) Type (F40T12, F96T12 or F96T12HO) and number of lamp or lamps with which the fluorescent lamp ballast is designed to be used.
(3) Each manufacturer of a covered product that is a general service fluorescent lamp, medium base compact fluorescent lamp, or general service incandescent lamp (including an incandescent reflector lamp), shall submit annually to the Commission a report for each lamp type in current production. The report shall contain the following information:
(i) Name and address of manufacturer;
(ii) All trade names under which the lamp is marketed;
(iii) Model number;
(iv) Starting serial number, date code or other means of identifying the date of manufacture (date of manufacture information must be included with only the first submission for each lamp type); and
(v) For all covered lamps, the test results based on 10 CFR § 430.23 for the lamp's wattage and light output ratings.
(vi) For all covered general service fluorescent lamps, the test results based on 10 CFR § 430.23 for the lamp's color rendering index and correlated color temperature.
(vii) For all covered incandescent lamps, the test results based on 10 CFR § 430.23 for the lamp's correlated color temperature.
(viii) For all covered compact fluorescent lamps, the test results based on 10 CFR § 430.23 for the lamp's life.
(4) Each manufacturer of a covered showerhead, faucet, water closet or urinal shall submit annually to the Commission a report for each basic model of such products in current production. The report shall contain the following information:
(i) Name and address of manufacturer;
(ii) All trade names under which the product is marketed;
(iii) Model number;
(iv) Starting serial number, date code or other means of identifying the date of manufacture (date of manufacture information must be included with only the first submission for each basic model);
(v) The product's water use, expressed in gallons and liters per flush (gpf and Lpf) or gallons and liters per minute (gpm and L/min) or per cycle (gpc and L/cycle) as determined in accordance with § 305.5.
(5) Each manufacturer of a metal halide lamp fixture shall submit annually to the Commission a report for each basic model of metal halide lamp fixture in current production. The report shall contain the following information:
(i) Name and address of manufacturer;
(ii) All trade names under which the metal halide lamp fixture is marketed;
(iii) Model number;
(iv) Starting serial number, date code or other means of identifying the date of manufacture (date of manufacture information must be included with only the first submission for each basic model);
(v) Type of ballast (e.g., pulse, probe, or electronic);
(vi) Nominal input voltage and frequency;
(vii) Ballast efficiency (as determined pursuant to 42 U.S.C. 6293(b)(18) ); and
(viii) Lamp type and wattage (or range of wattages) with which the metal halide lamp fixture is designed to be used.
(b) (1) All data required by § 305.8(a) except serial numbers shall be submitted to the Commission annually, on or before the following dates:
Product category Deadline for data submission
Refrigerators Aug. 1
Refrigerators-freezers Aug. 1
Freezers Aug. 1
Central air conditioners July 1
Heat pumps July 1
Dishwashers June 1
Water heaters May 1
Room air conditioners May 1
Furnaces May 1
Pool heaters May 1
Clothes washers Oct. 1
Fluorescent lamp ballasts Mar. 1
Showerheads Mar. 1
Faucets Mar. 1
Water closets Mar. 1
Ceiling fans Mar. 1
Code of Federal Regulations 270
Urinals Mar. 1
Metal halide lamp fixtures Sept. 1
Fluorescent lamps Mar. 1
Medium Base Compact Fluorescent Lamps Mar. 1
General Service Incandescent Lamps
Incandescent Lamps, incl. Reflector Lamps Mar. 1
(2) All revisions to such data (both additions to and deletions from the preceding data) shall be submitted to the Commission as part of the next annual report period.
(c) All information required by paragraph (a) of this section must be submitted for new models prior to any distribution of such model. Models subject to design or retrofit alterations which change the data contained in any annual report shall be reported in the manner required for new models. Models which are discontinued shall be reported in the next annual report.

Code of Federal Regulations

[52 FR 46894, Dec. 10, 1987, as amended at 54 FR 28035, July 5, 1989; 59 FR 54965, Oct. 25, 1993; 59 FR 49564, Sept. 28, 1994; 59 FR 67527, Dec. 29, 1994; 60 FR 14210, Mar. 16, 1995; 67 FR 35008, May 17, 2002; 68 FR 8449, Feb. 21, 2003; 73 FR 63067, Oct. 23, 2008; 75 FR 41714, July 19, 2010]