431.264—Uniform test method for the measurement of flow rate for commercial prerinse spray valves.
(a) Scope.
This section provides the test procedure for measuring, pursuant to EPCA, the water consumption flow rate of commercial prerinse spray valves.
(b) Testing and Calculations.
The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed in gallons per minute (gpm) or liters per minute (L/min), shall be conducted in accordance with the test requirements specified in sections 4.1 and 4.2 (Summary of Test Method), 5.1 (Significance and Use), 6.1 through 6.9 (Apparatus) except 6.5, 9.1 through 9.5 (Preparation of Apparatus), and 10.1 through 10.2.5. (Procedure), and calculations in accordance with sections 11.1 through 11.3.2 (Calculation and Report) of the ASTM F2324-03, “Standard Test Method for Prerinse Spray Valves.” (Incorporated by reference, see § 431.263) Perform only the procedures pertinent to the measurement of flow rate. Record measurements at the resolution of the test instrumentation. Round off calculations to the same number of significant digits as the previous step. Round the final water consumption value to one decimal place as follows:
(1)
A fractional number at or above the midpoint between two consecutive decimal places shall be rounded up to the higher of the two decimal places; or
(2)
A fractional number below the midpoint between two consecutive decimal places shall be rounded down to the lower of the two decimal places.