983.150—Aflatoxin regulations.
(a) Maximum level.
No handler shall ship for domestic human consumption, pistachios that exceed an aflatoxin level of 15 ppb. All shipments must also be covered by an aflatoxin inspection certificate. Pistachios that fail to meet the aflatoxin requirements shall be disposed in such manner as described in Failed lots/rework procedure of this part.
(b) Change in level.
The committee may recommend to the Secretary changes in the aflatoxin level specified in this section. If the Secretary finds, on the basis of such recommendation or other information, that such an adjustment of the aflatoxin level would tend to effectuate the declared policy of the Act, such change shall be made accordingly.
(c) Transfers between handlers.
Transfers between handlers within the production area are exempt from the aflatoxin regulation of this section.
(d) Aflatoxin testing procedures.
To obtain an aflatoxin inspection certificate, each lot to be certified shall be uniquely identified, be traceable from testing through shipment by the handler, and be subjected to the following:
(1) Samples for testing.
Prior to testing, a sample shall be drawn from each lot (“lot samples”) of sufficient weight to comply with Table 1 and Table 2 of this section.
(2) Test samples for aflatoxin.
Prior to submission of samples to an accredited laboratory for aflatoxin analysis, one sample (“test sample”) shall be created from the pistachios designated for aflatoxin testing in compliance with Tables 1 and 2 of this paragraph for inshell and kernel pistachio lots that weigh up to and including 4,400 pounds. For lot sizes larger than 4,400 pounds, two samples (“test samples”) shall be created equally from the pistachios designated for aflatoxin testing in compliance with the requirements to Tables 1 and 2 of this paragraph. The test samples shall be prepared by, or under the supervision of an inspector, or as approved under an alternative USDA-recognized inspection program. The test samples shall be designated by an inspector as Test Sample #1 and Test Sample #2. Each sample shall be placed in a suitable container, with the lot number clearly identified, and then submitted to an accredited laboratory. The gross weight of the inshell lot sample for aflatoxin testing and the minimum number of incremental samples required are shown in Table 1 of this paragraph. The gross weight of the kernel lot sample for aflatoxin testing and the minimum number of incremental samples required is shown in the Table 2 of this paragraph.
Lot weight(lbs.) | Minimum numberof incrementalsamples for thelot sample | Total weight oflot sample(kilograms) | Weight of testsample(kilograms) |
---|---|---|---|
220 or less | 10 | 2.0 | 2.0 |
221-440 | 15 | 3.0 | 3.0 |
441-1,100 | 20 | 4.0 | 4.0 |
1,101-2,200 | 30 | 6.0 | 6.0 |
2,201-4,400 | 40 | 8.0 | 8.0 |
Code of Federal Regulations
548
|
|||
4,401-11,000 | 60 | 12.0 | 6.0 |
11,001-22,000 | 80 | 16.0 | 8.0 |
22,001-150,000 | 100 | 20.0 | 10.0 |
Lot weight(lbs.) | Minimum numberof incrementalsamples for thelot sample | Total weight oflot sample(kilograms) | Weight of testsample(kilograms) |
---|---|---|---|
220 or less | 10 | 1.0 | 1.0 |
221-440 | 15 | 1.5 | 1.5 |
441-1,100 | 20 | 2.0 | 2.0 |
1,101-2,200 | 30 | 3.0 | 3.0 |
2,201-4,400 | 40 | 4.0 | 4.0 |
4,401-11,000 | 60 | 6.0 | 3.0 |
11,001-22,000 | 80 | 8.0 | 4.0 |
22,001-150,000 | 100 | 10.0 | 5.0 |
(3) Testing of pistachios.
Test samples shall be received and logged by an accredited laboratory and each test sample shall be prepared and analyzed using High Pressure Liquid Chromatography (HPLC), Vicam Method (Aflatest), or other methods as recommended by not fewer than eight members of the committee and approved by the Secretary. The aflatoxin level shall be calculated on a kernel weight basis.
(4) Certification of lots “negative” as to aflatoxin.
(i)
Lots which require a single test sample will be certified as “negative” on the aflatoxin certificate if the sample has an aflatoxin level at or below 15 ppb. If the aflatoxin level is above 15 ppb, the lot fails and the accredited laboratory shall fill out a failed lot notification report as specified in §§ 983.52 and 983.152.
(ii)
Lots which require two test samples will be certified as “negative” on the aflatoxin inspection certificate if Test Sample #1 has an aflatoxin level at or below 10 ppb. If the aflatoxin level of Test Sample #1 is above 20 ppb, the lot fails and the accredited laboratory shall fill out a failed lot notification report as specified in §§ 983.52 and 983.152. If the aflatoxin level of Test Sample #1 is above 10 ppb and at or below 20 ppb, the accredited laboratory may at the handler's discretion analyze Test Sample #2 and the test results of Test Samples #1 and #2 will be averaged. Alternately, the handler may elect to withdraw the lot from testing, rework the lot, and resubmit it for testing after reworking. If the handler directs the laboratory to proceed with the analysis of Test Sample #2, a lot will be certified as negative to aflatoxin and the laboratory shall issue an aflatoxin inspection certificate if the averaged results of Test Sample #1 and Test Sample #2 is at or below 15 ppb. If the averaged aflatoxin level of Test Samples #1 and #2 is above 15 ppb, the lot fails and the accredited laboratory shall fill out a failed lot notification report as specified in §§ 983.52 and 983.152.
(iii)
The accredited laboratory shall send a copy of the failed lot notification report to the Committee and to the failed lot's owner within 10 working days of any failure described in this section. If the lot is certified as negative as described in this section, the aflatoxin inspection certificate shall certify the lot using a certification form identifying each lot by weight, grade, and date. The certification expires for the lot or remainder of the lot after 12 months.
(5) Certification of aflatoxin levels.
Each accredited laboratory shall complete aflatoxin testing and reporting and shall certify that every lot of pistachios shipped domestically does not exceed the aflatoxin levels as required in paragraph (a) of this section or as provided under § 983.50. Each handler shall keep a record of each test, along with a record of final shipping disposition. These records must be maintained for three years beyond the production year of their applicability, and are subject to audit by the Secretary or the committee at any time.
(6) Test samples that are not used for analysis.
If a handler does not elect to use Test Sample #2 for certification purposes, the handler may request that the laboratory return it to the handler.