572.33—Neck.

(b) When the head and neck assembly (consisting of the parts 78051-61X, revision C; -90, revision A; -84; -94; -98; -104, revision F; -303, revision E; -305; -306; -307, revision X) which has a six axis neck transducer (Drawing number C-1709, Revision D, titled “Neck transducer,” dated February 1, 1993.) installed in conformance with § 572.36(d), is tested in accordance with paragraph (c) of this section, it shall have the following characteristics:

Code of Federal Regulations

Code of Federal Regulations 35
[Please see PDF for image: ER20MY97.000 ]

Code of Federal Regulations

Code of Federal Regulations 36
[Please see PDF for image: ER20MY97.001 ]

Code of Federal Regulations

Code of Federal Regulations 37
[Please see PDF for image: EC01AU91.165 ]
Table A—Flexion Pendulum Deceleration vs. Time Pulse
Time (ms) Flexion deceleration level (g)
10 22.50-27.50
20 17.60-22.60
30 12.50-18.50
Any other time above 30 ms 29 maximum.
Table B—Extension Pendulum Deceleration vs. Time Pulse
Time (ms) Extension deceleration level (g)
10 17.20-21.20
20 14.00-19.00
30 11.00-16.00
Any other time above 30 ms 22 maximum.
[51 FR 26701, July 25, 1986, as amended at 53 FR 8765, Mar. 17, 1988; 62 FR 27514, May 20, 1997]