179.500-4—Thickness of wall.

Code of Federal Regulations

P = [10S(D 2d 2)] / [7(D 2 d 2)]
Where:
P = Maximum marked test pressure permitted;

Code of Federal Regulations

S = U / 3.0
Where:
U = Tensile strength of that specimen which shows the lower tensile strength of the two specimens taken from the tank and tested as prescribed in § 179.500-7(b).
3 = Factor of safety.
(D2 − d2/(D2 d2) = The smaller value obtained for this factor by the operations specified in § 179.500-4(c).
d = Maximum inside diameter (inches) for the location under consideration; to be determined by direct measurement to an accuracy of 0.05 inch.
t = Minimum thickness of wall for the location under consideration; to be determined by direct measurement to an accuracy of 0.001 inch.
Take D = d 2t.
Calculate the value of (D2−d2)/(D2 d2)
[29 FR 18995, Dec. 29, 1964. Redesignated at 32 FR 5606, Apr. 5, 1967, and amended by Amdt. 179-31, 47 FR 43067, Sept. 30, 1982; 66 FR 45391, Aug. 28, 2001]