179.301—Individual specification requirements for multi-unit tank car tanks.
DOT specification | 106A500-X | 106A800-X | 110A500-W | 110A600-W | 110A800-W | 110A1000-W |
---|---|---|---|---|---|---|
Minimum required bursting pressure, psig | (1) | (1) | 1250 | 1500 | 2000 | 2500 |
Minimum thickness shell, inches | 13/32 | 11/16 | 11/32 | 3/8 | 15/32 | 19/32 |
Test pressure, psig (see § 179.300-16 ) | 500 | 800 | 500 | 600 | 800 | 1000 |
Safety relief devices, psig (see § 179.300-15 ) | ||||||
Start-to-discharge, or burst maximum, p.s.i. | 375 | 600 | 375 | 450 | 600 | 700 |
Vapor-tight, minimum psig | 300 | 480 | 300 | 360 | 480 | 650 |
1 None specified. |