179.220-25—Stamping.
To certify that the tank complies with all specification requirements, each outer shell must be plainly and permanently stamped in letters and figures at least 3/8 -inch high into the metal near the center of both outside heads as follows:
Examples of required stamping | |
---|---|
Specifications | DOT-115A60W6. |
Inner container: | |
Material | ASTM A240-316L. |
Shell thickness | Shell 0.167 in. |
Head thickness | Head 0.150 in. |
Tank builders initials | ABC. |
Date of original test | 00-0000. |
Outer shell: | |
Material | ASTM A285-C. |
Tank builders initials | WYZ. |
Code of Federal Regulations
1104
|
|
Car assembler (if other than inner container or outer shell builders) | DEF. |
[Amdt. 179-9, 36 FR 21343, Nov. 6, 1971]