179.200-7—Materials.

Specifications Minimum tensile strength (p.s.i.) welded condition 1 Minimum elongation in 2 inches (percent) weld metal (longitudinal)
AAR TC 128, Gr. B 81,000 19
ASTM A 516 2 70,000 20
1 Minimum stresses to be used in calculations.
2 This specification is incorporated by reference (IBR, see § 171.7 of this subchapter).
Specifications Minimum tensile strength (p.s.i.) welded condition 3,4 Minimum elongation in 2 inches (percent) 0 temper weld metal (longitudinal)
ASTM B 209, Alloy 5052 1 25,000 18
ASTM B 209, Alloy 5083 2 38,000 16
ASTM B 209, Alloy 5086 1 35,000 14
ASTM B 209, Alloy 5154 1 30,000 18
ASTM B 209, Alloy 5254 1 30,000 18
ASTM B 209, Alloy 5454 1 31,000 18
ASTM B 209, Alloy 5652 1 25,000 18
1 For fabrication, the parent plate material may be 0, H112, or H32 temper, but design calculations must be based on minimum tensile strength shown.
2 0 temper only.
3 Weld filler metal 5556 must not be used.
4 Maximum stresses to be used in calculations.
Specifications Minimum tensile strength (p.s.i.) welded condition 1 Minimum elongation in 2 inches (percent) weld metal (longitudinal)
ASTM A 240/A 240M (incorporated by reference; see § 171.7 of this subchapter), Type 304 75,000 30
ASTM A 240/A 240M (incorporated by reference; see § 171.7 of this subchapter), Type 304L 70,000 30
ASTM A 240/A 240M (incorporated by reference; see § 171.7 of this subchapter), Type 316 75,000 30
ASTM A 240/A 240M (incorporated by reference; see § 171.7 of this subchapter), Type 316L 70,000 30
1 Maximum stresses to be used in calculations.
2 High alloy steel materials used to fabricate tank and expansion dome, when used, must be tested in accordance with Practice A of ASTM Specification A 262 titled, “Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels” (IBR; see § 171.7 of this subchapter). If the specimen does not pass Practice A, Practice B or C must be used and the corrosion rates may not exceed the following:
Test procedure Material Corrosion rate i.p.m.
Practice B Types 304, 304L, 316, and 316L 0.0040
Practice C Type 304L .0020
Type 304L and Type 316L test specimens must be given a sensitizing treatment prior to testing. (A typical sensitizing treatment is 1 hour at 1250 F.)
Specifications Minimum tensile strength (psi) welded condition 1 Minimum elongation in 2 inches (percent) weld metal (longitudinal)
ASTM B 162 2 40,000 20
Specifications Minimum tensile strength (p.s.i.) welded condition 1 Minimum elongation in 2 inches (percent) weld metal (longitudinal)
ASTM A 302, Gr. B 80,000 20
1 Maximum stresses to be used in calculations.
[Amdt. 179-10, 36 FR 21349, Nov. 9, 1971; 36 FR 21893, Nov. 17, 1971, as amended by Amdt.179-28, 46 FR 49906, Oct. 8, 1981; Amdt. 179-40, 52 FR 13046, Apr. 20, 1987; Amdt. 179-52, 61 FR 28680, June 5, 1996; 66 FR 45186, Aug. 28, 2001; 67 FR 51660, Aug. 8, 2002; 68 FR 75761, Dec. 31, 2003; 70 FR 34076, June 13, 2005]