173.319—Cryogenic liquids in tank cars.

Pressure Control Valve Setting or Relief Valve Setting
Maximum start-to-discharge pressure (psig) Maximum permitted filling density (percent by weight)
Ethylene Ethylene Ethlyene Hydrogen
17 6.60.
45 52.8
75 51.1 51.1
Maximum pressure when offered for transportation 10 psig 10 psig 20 psig
Design service temperature Minus 260 °F Minus 260 °F Minus 155 °F Minus 423 °F.
Specification (see § 180.507(b)(3) of this subchapter) 113D60W113C60W 113C120W 113D120W 113A175W.113A60W.

Code of Federal Regulations

( 49 U.S.C. 1803, 1804, 1808 ; 49 CFR 1.53 , app. A to part 1 )
[Amdt. 173-166, 48 FR 27698, June 16, 1983, as amended by Amdt. 173-245, Sept. 21, 1995; 65 FR 58630, Sept. 29, 2000; 66 FR 45184, 45379, 45383, Aug. 28, 2001; 70 FR 34076, June 13, 2005]