173.318—Cryogenic liquids in cargo tanks.

Pressure Control Valve Setting or Relief Valve Setting
Maximum set-to-discharge pressure (psig) Maximum permitted filling density (percent by weight)
Air Argon Helium Nitrogen Oxygen
26 12.5
30 80.3 129 12.5 74 105
40 79.2 12.5
50 78.0 12.5
55 77.3 125 12.5 71 102
60 76.9 12.5
80 75.3 12.5
85 75.1 121 12.5 99
100 73.0 12.5
105 73.7 12.5 67
120 72.2 12.5
140 71.4 12.5
145 70.9 115 12.5 64 94
180 68.3 12.5
200 67.3 110 12.5 61 91
250 63.3 106 12.5 57 87
275 62.3 105 12.5 56 86
325 59.4 101 53 83
Design service temperature −320 °F −320 °F −452 °F −320 °F −320 °F
Pressure Control Valve Setting or Relief Valve Setting
Maximum set-to-discharge pressure (psig) Maximum permitted filling density (percent by weight)
Carbon monoxide Ethylene Hydrogen Methane or natural gas
13 6.6
15 75.0 6.6 40.5
17 74.0 6.6
20 53.5 40.0
25 73.0
30 72.0 52.7 6.3 39.1
35
40 52.0 38.6
45 71.5
50 51.4 6.0 38.2
55
60 50.8
70 50.2 5.7 37.5
90 49.2
95
Code of Federal Regulations 636
100 48.4 5.4 36.6
115 48.2
125 5.0
150 4.5
175 62.5 45.8
285 56.0
Design service temperature −320 °F −155 °F −423 °F −260 °F
OWTT = (MRHT − 24) / 2
OWTT = MRHT − 48
[Amdt. 173-166, 48 FR 27696, June 16, 1983]