173.133—Assignment of packing group and hazard zones for Division 6.1 materials.

(a) The packing group of Division 6.1 materials shall be as assigned in column 5 of the § 172.101 table. When the § 172.101 table provides more than one packing group or hazard zone for a hazardous material, the packing group and hazard zone shall be determined by applying the following criteria:
Packing group Oral toxicity LD50 (mg/kg) Dermal toxicity LD50(mg/kg) Inhalation toxicity by dusts and mists LC50 (mg/L)
I ≤5.0 ≤50 ≤0.2
II >5.0 and ≤50 >50 and ≤200 >0.2 and ≤2.0
III >50 and ≤300 >200 and ≤1000 >2.0 and ≤4.0
Packing Group Vapor concentration and toxicity
I (Hazard Zone A) V ≥ 500 LC50 and LC50 ≤ 200 mL/M3.
I (Hazard Zone B) V ≥ 10 LC50; LC50 ≤ 1000 mL/m3; and the criteria for Packing Group I, Hazard Zone A are not met.
II V ≥ LC50; LC50 ≤ 3000 mL/m3; and the criteria for Packing Group I, are not met.
III V ≥ .2 LC50; LC50 ≤ 5000 mL/m3; and the criteria for Packing Groups I and II, are not met.
Note 1: V is the saturated vapor concentration in air of the material in mL/m3 at 20 °C and standard atmospheric pressure.
Note 2: A liquid in Division 6.1 meeting criteria for Packing Group I, Hazard Zones A or B stated in paragraph (a)(2) of this section is a material poisonous by inhalation subject to the additional hazard communication requirements in §§ 172.203(m), 172.313 and table 1 of § 172.504(e) of this subchapter.

Code of Federal Regulations

Code of Federal Regulations 504
[Please see PDF for image: EC02MR91.063 ]
where
fi = mole fraction of the ith component substance of the liquid.
LC50i = mean lethal concentration of the ith component substance in mL/m3
where:
Pi = partial pressure of the ith component substance in kPa at 20 °C and one atmospheric pressure. Pi may be calculated according to Raoult's Law using appropriate activity coefficients. Where activity coefficients are not available, the coefficient may be assumed to be 1.0.
Packaging group(hazard zone) Ratio of volatility and LC50
I (Hazard Zone A) R ≥ 500 and LC50 (mixture) ≤ 200 mL/m3.
I (Hazard Zone B) R ≥ 10 and LC50 (mixture) ≤ 1000 mL/m3; and the criteria for Packing Group I, Hazard Zone A are not met.
II R ≥ 1 and LC50 (mixture) ≤ 3000 mL/m3; and the criteria for Packing Group I, Hazard Zones A and B are not met.
III R ≥ 1/5 and LC50 (mixture) ≤ 5000 mL/m3; and the criteria for Packing Group I, Hazard Zones A and B and Packing Group II are not met.
[Amdt. 173-224, 55 FR 52634, Dec. 21, 1990, as amended at 56 FR 66268-66270, Dec. 20, 1991; 57 FR 45461-45463, Oct. 1, 1992; Amdt. 173-234, 58 FR 51532, Oct. 1, 1993; Amdt. 173-138, 59 FR 49133, Sept. 26, 1994; Amdt. 173-255, 61 FR 50626, Sept. 26, 1996; 66 FR 45183, 45380, Aug. 28, 2001; 66 FR 49556, Sept. 28, 2001; 69 FR 54046, Sept. 7, 2004; 71 FR 54395, Sept. 14, 2006; 71 FR 78631, Dec. 29, 2006; 74 FR 53188, Oct. 16, 2009]