15.239—Operation in the band 88-108 MHz.
(a)
Emissions from the intentional radiator shall be confined within a band 200 kHz wide centered on the operating frequency. The 200 kHz band shall lie wholly within the frequency range of 88-108 MHz.
(b)
The field strength of any emissions within the permitted 200 kHz band shall not exceed 250 microvolts/ meter at 3 meters. The emission limit in this paragraph is based on measurement instrumentation employing an average detector. The provisions in § 15.35 for limiting peak emissions apply.
(c)
The field strength of any emissions radiated on any frequency outside of the specified 200 kHz band shall not exceed the general radiated emission limits in § 15.209.
(d)
A custom built telemetry intentional radiator operating in the frequency band 88-108 MHz and used for experimentation by an educational institute need not be certified provided the device complies with the standards in this part and the educational institution notifies the Engineer in Charge of the local FCC office, in writing, in advance of operation, providing the following information:
(3)
A description of the device, including the operating frequency, RF power output, and antenna; and,
[54 FR 17714, Apr. 25, 1989; 54 FR 32340, Aug. 7, 1989]