28.350—General requirements for electrical systems.
(a)
Electrical equipment exposed to the weather or in a location exposed to seas must be waterproof, watertight, or enclosed in a watertight housing.
(c)
As far as practicable, electrical equipment must not be installed in lockers used to store paint, oil, turpentine, or other flammable or combustible liquid. If electrical equipment, such as lighting, is necessary in these spaces, it must be explosion-proof or intrinsically safe.
(d)
Explosion-proof and intrinsically safe equipment must meet the requirements of 46 CFR part 111, subpart .
(f)
Each vessel with a nonmetallic hull must have a continuous, non-current carrying grounding conductor which connects together the enclosures and frames of electrical equipment and which connects metallic items such as engines, fuel tanks, and equipment enclosures to a common ground point.
(g)
The equipment grounding conductor must be sized in accordance with section 250-95 of NFPA Standard 70.