28.140—Operational readiness, maintenance, and inspection of lifesaving equipment.
(a)
The master or individual in charge of a vessel must ensure that each item of lifesaving equipment must be in good working order, ready for immediate use, and readily accessible before the vessel leaves port and at all times when the vessel is operated.
(b)
Each item of lifesaving equipment, including unapproved equipment, must be maintained and inspected in accordance with:
(2)
The servicing procedure under the subpart of this chapter applicable to the item's approval; and
(c)
An inflatable liferaft or inflatable buoyant apparatus must be serviced no later than the month and year on its servicing sticker affixed under 46 CFR 160.151-57(n), and whenever the container is damaged or the container straps or seals are broken. It must be serviced at a facility specifically approved by the Commandant for the particular brand.
(d)
An escape route from a space where an individual may be employed or an accommodation space must not be obstructed.
Item | Interval | Regulation | |
---|---|---|---|
Monthly | Annually | ||
(1) Inflatable wearable personal flotation device (Type V commercial hybrid) | Servicing | 28.140 | |
(2) Personal flotation devices, exposure suits and immersion suits | Inspect, clean and repair as necessary | 28.140 | |
(3) Buoyant apparatus and life floats | Inspect, clean and repair as necessary | 28.140 | |
(4) Inflatable liferaft | Servicing 1 | 28.140 | |
(5) Inflatable buoyant apparatus | Servicing 1 | 28.140 | |
(6) Hydrostatic release | Servicing 1 | 28.140 | |
Code of Federal Regulations
307
|
|||
(7) Disposable hydrostatic release | Replace on or before expiration date | 28.140 | |
(8) Undated batteries | Replace | 28.140 | |
(9) Dated batteries 2 and other items | Replace on or before expiration date | 25.26-50, 28.140 | |
(10) EPIRB | Test | 25.26-50 | |
1 For a new liferaft or inflatable buoyant apparatus, the first annual servicing may be deferred to two years from the date of first packing if so indicated on the servicing sticker. | |||
2 Water activated batteries must be replaced whenever they are used. |
[CGD 88-079, 56 FR 40393, Aug. 14, 1991; 56 FR 49822, Oct. 1, 1991, as amended at USCG-2001-11118, 67 FR 58540, Sept. 17, 2002; USCG-2004-18884, 69 FR 58344, Sept. 30, 2004]