181.420—Pre-engineered fixed gas fire extinguishing systems.
(2)
Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector;
(3)
Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and
(b)
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:
(3)
A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section.
(c)
Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such a system.