174.185—Intact stability.
(a)
Each OSV must be shown by design calculations to meet, under each condition of loading and operation, the minimal requirements for metacentric height (GM) in § 170.170 of this chapter, and in either § 170.173 of this chapter or paragraphs (b) through (e) of this section.
(b)
The area under each righting arm curve must be at least 0.08 meter-radians (15 foot-degrees) up to the smallest of the following angles:
(e)
The freeboard at the stern must be equal to the freeboard calculated to comply with subchapter E of this chapter or to the value taken from Table 174.185, whichever is less.
(f)
For paragraphs (b) and (d) of this section, at each angle of heel an OSV's righting arm may be calculated considering either—
(g)
For the purpose of paragraphs (b) and (d) of this section, the method of calculating righting arms chosen must be the same for all calculations.
LBP in meters (feet) | Freeboard at stern in millimeters (inches) |
---|---|
Less than 20 (65) | 300 (12) |
20 (65) but less than 30 (100) | 380 (15) |
30 (100) but less than 40 (130) | 400 (18) |
40 (130) but less than 50 (155) | 500 (20) |
50 (155) but less than 60 (190) | 560 (22) |
60 (190) but less than 70 (230) | 610 (24) |
70 (230) and greater | 660 (26) |