169.608—Non-integral keel cooler installations
        
        (a) 
         Hull penetrations for non-integral keel cooler installations must be made through a cofferdam or at a sea chest.
    
    
        
        (b) 
         Non-integral keel coolers must be suitably protected against damage from debris and grounding by recessing the unit into the hull or by the placement of protective guards.
    
    
    [CGD 83-005, 51 FR 896, Jan. 9, 1986, as amended by USCG-2000-7790, 65 FR 58464, Sept. 29, 2000]