154.506—Mechanical expansion joint: Limits in a piping system.
Mechanical expansion joints in a piping system outside of a cargo tank:
(a)
May be installed only if offsets, loops or bends cannot be installed due to limited space or piping arrangement;
(b)
Must be a bellows type; and
(c)
Must not have insulation or a cover unless necessary to prevent damage.