154.1010—Electrical equipment in gas-dangerous space or zone.
(a)
Except as allowed in this section, electrical equipment must not be installed in a gas-dangerous space or zone.
(1)
Low liquid level, motor current, or pump discharge pressure automatically shuts down power to the pump motor if the pump loses suction;
(2)
There is an audible and visual alarm at the cargo control station that actuates if the motor shuts down under the requirements of paragraph (c)(1) of this section; and
(e)
A hold space that has a tank that is not required to have a secondary barrier under § 154.459 may only have:
(f)
A space that is separated by a gastight steel boundary from a hold space that has a cargo tank that must have a secondary barrier, under the requirements of § 154.459, may only have:
(k)
A space, except those under paragraphs (e) through (j) of this section, that has a direct opening to a gas-dangerous space or zone may only have the electrical equipment allowed in the gas-dangerous space or zone.