127.110—Plans and specifications required for new construction.
Each applicant for approval of plans and for an original Certificate of Inspection shall submit three copies of the following:
(c) Subdivision and stability.
[For plans required for subdivision and stability, see subchapter S of this chapter.]
(2)
Piping diagrams of the following Class II systems (the builder's certification of Class II non-vital piping systems must accompany the piping diagrams in compliance with § 128.220(c) of this subchapter):
(5)
Piping diagrams of each system containing any flammable, combustible, or hazardous liquid including—
(e) Electrical engineering.
(1)
For each vessel of less than 100 gross tons, the following plans must be submitted:
(i)
Arrangement of electrical equipment (plan and profile) with equipment identified as necessary to show compliance with this subchapter.
(ii)
Electrical one-line diagram that includes wire types and sizes, overcurrent-device rating and setting, and type of electrical-equipment enclosure (drip-proof, watertight, or the like).
(2)
For each vessel of 100 or more gross tons, the plans required by § 110.25 of this chapter must be submitted.
(f) Automation.
For each vessel of 100 or more gross tons, where automated systems are provided to replace specific personnel in the control and observation of the propulsion systems and machinery spaces, or to reduce the level of crew associated with the engine department, the following plans must be submitted: