91.311—Test conditions.
(a) General requirements.
(1)
Ambient temperature levels encountered by the test engine throughout the test sequence may not be less than 20 °C nor more than 30 °C.
(2)
Calculate all volumes and volumetric flow rates at standard conditions for temperature and pressure. Use these conditions consistently throughout all calculations. Standard conditions for temperature and pressure are 25 °C and 101.3 kPa.
(b) Engine test conditions.
Measure the absolute temperature (designated as T and expressed in Kelvin) of the engine air at the inlet to the engine and the dry atmospheric pressure (designated as p
s and expressed in kPa. Determine the parameter f according to the following provisions:
(3)
For a test to be recognized as valid, the parameter f must be between the limits as shown below: