467.25—Pretreatment standards for existing sources.
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in aluminum forming process wastewater introduced into a POTW shall not exceed the following values:
|
mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions |
Chromium |
0.057 |
0.024 |
Cyanide |
0.038 |
0.016 |
Zinc |
0.190 |
0.079 |
TTO |
0.090 |
|
Oil and grease (alternate monitoring parameter) |
6.8 |
3.4 |
|
mg/off-kg (lb/million off-lbs) of aluminum cast by semi-continuous methods |
Chromium |
0.59 |
0.24 |
Cyanide |
0.39 |
0.16 |
Zinc |
1.94 |
0.81 |
TTO |
0.92 |
|
Oil and grease (alternate monitoring parameter) |
69 |
35 |
|
mg/off-kg (lb/million off-lbs) of aluminum quenched |
Chromium |
0.90 |
0.37 |
Cyanide |
0.59 |
0.25 |
Zinc |
2.98 |
1.25 |
TTO |
1.41 |
|
Oil and grease (alternate monitoring parameter) |
110 |
53 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.079 |
0.032 |
Cyanide |
0.052 |
0.022 |
Zinc |
0.262 |
0.109 |
TTO |
0.124 |
|
Oil and grease (alternate monitoring parameter) |
9.3 |
4.7 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.61 |
0.25 |
Cyanide |
0.41 |
0.17 |
Zinc |
2.03 |
0.85 |
TTO |
0.96 |
|
Oil and grease (alternate monitoring parameter) |
73 |
36 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.85 |
0.35 |
Cyanide |
0.56 |
0.23 |
Zinc |
2.83 |
1.18 |
TTO |
1.34 |
|
Oil and grease (alternate monitoring parameter) |
100 |
50 |
Code of Federal Regulations
[48 FR 49149, Oct. 24, 1983; 49 FR 11631, 11632, and 11633, Mar. 27, 1984, as amended at 53 FR 52369 and 52370, Dec. 27, 1988]
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in aluminum forming process wastewater introduced into a POTW shall not exceed the following values:
|
mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions |
Chromium |
0.057 |
0.024 |
Cyanide |
0.038 |
0.016 |
Zinc |
0.190 |
0.079 |
TTO |
0.090 |
|
Oil and grease (alternate monitoring parameter) |
6.8 |
3.4 |
|
mg/off-kg (lb/million off-lbs) of aluminum cast by semi-continuous methods |
Chromium |
0.59 |
0.24 |
Cyanide |
0.39 |
0.16 |
Zinc |
1.94 |
0.81 |
TTO |
0.92 |
|
Oil and grease (alternate monitoring parameter) |
69 |
35 |
|
mg/off-kg (lb/million off-lbs) of aluminum quenched |
Chromium |
0.90 |
0.37 |
Cyanide |
0.59 |
0.25 |
Zinc |
2.98 |
1.25 |
TTO |
1.41 |
|
Oil and grease (alternate monitoring parameter) |
110 |
53 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.079 |
0.032 |
Cyanide |
0.052 |
0.022 |
Zinc |
0.262 |
0.109 |
TTO |
0.124 |
|
Oil and grease (alternate monitoring parameter) |
9.3 |
4.7 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.61 |
0.25 |
Cyanide |
0.41 |
0.17 |
Zinc |
2.03 |
0.85 |
TTO |
0.96 |
|
Oil and grease (alternate monitoring parameter) |
73 |
36 |
|
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched |
Chromium |
0.85 |
0.35 |
Cyanide |
0.56 |
0.23 |
Zinc |
2.83 |
1.18 |
TTO |
1.34 |
|
Oil and grease (alternate monitoring parameter) |
100 |
50 |
Code of Federal Regulations
[48 FR 49149, Oct. 24, 1983; 49 FR 11631, 11632, and 11633, Mar. 27, 1984, as amended at 53 FR 52369 and 52370, Dec. 27, 1988]