420.104—New source performance standards (NSPS).
The discharge of wastewater pollutants from any new source subject to this subpart shall not exceed the standards set forth below.
(a) Cold rolling mills—
(1) Recirculation—single stand.
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.00125 |
0.000626 |
O&G |
0.000522 |
0.000209 |
Chromium 1
|
0.0000209 |
0.0000084 |
Code of Federal Regulations
441
|
Lead |
0.0000094 |
0.0000031 |
Nickel 1
|
0.0000188 |
0.0000063 |
Zinc |
0.0000063 |
0.0000021 |
Naphthalene |
0.0000021 |
|
Tetrachloroethylene |
0.0000031 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are cotreated with descaling or combination acid pickling wastewaters. |
2 Within the range of 6.0 to 9.0. |
(2) Recirculation—multiple stands.
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.00250 |
0.00125 |
O&G |
0.00104 |
0.000417 |
Chromium 1
|
0.0000418 |
0.0000167 |
Lead |
0.0000188 |
0.0000063 |
Nickel 1
|
0.0000376 |
0.0000125 |
Zinc |
0.0000125 |
0.0000042 |
Naphthalene |
0.0000042 |
|
Tetrachloroethylene |
0.0000063 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters. |
2 Within the range of 6.0 to 9.0. |
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.0326 |
0.0163 |
O&G |
0.0136 |
0.00543 |
Chromium 1
|
0.000543 |
0.000217 |
Lead |
0.000244 |
0.0000814 |
Nickel 1
|
0.000488 |
0.000163 |
Zinc |
0.000163 |
0.0000542 |
Naphthalene |
0.0000542 |
|
Tetrachloroethylene |
0.0000813 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastwaters are treated with descaling or combination acid pickling wastewaters. |
2 Within the range of 6.0 to 9.0. |
(4) Direct application—single stand.
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.00626 |
0.00313 |
O&G |
0.00261 |
0.00104 |
Chromium 1
|
0.000104 |
0.0000418 |
Lead |
0.0000469 |
0.0000156 |
Nickel 1
|
0.0000939 |
0.0000313 |
Zinc |
0.0000313 |
0.0000104 |
Naphthalene |
0.0000104 |
|
Tetrachloro-ethylene |
0.0000156 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling watewaters. |
2 Within the range of 6.0 to 9.0. |
(5) Direct application—multiple stands.
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.0726 |
0.0363 |
O&G |
0.0302 |
0.0121 |
Chromium 1
|
0.00121 |
0.000484 |
Lead |
0.000545 |
0.000182 |
Nickel 1
|
0.00109 |
0.000363 |
Zinc |
0.000363 |
0.000121 |
Naphthalene |
0.000121 |
|
Tetrachloro-ethylene |
0.000182 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling watewaters. |
2 Within the range of 6.0 to 9.0. |
(b) Cold worked pipe and tube mills—
(1) Using water.
Subpart J
|
Kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.00125 |
0.000626 |
O&G |
0.000522 |
0.000209 |
Chromium 1
|
0.0000209 |
0.0000084 |
Lead |
0.0000094 |
0.0000031 |
Nickel 1
|
0.0000188 |
0.0000063 |
Zinc |
0.0000063 |
0.0000021 |
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are cotreated with descaling or combination acid pickling wastewaters. |
2 Within the range of 6.0 to 9.0. |
Subpart J
|
kg/kkg (pounds per 1,000 lb) of product |
TSS |
0.00125 |
0.000626 |
O&G |
0.000522 |
0.000209 |
Chromium 1
|
0.0000209 |
0.0000084 |
Lead |
0.0000094 |
0.0000031 |
Nickel 1
|
0.0000188 |
0.0000063 |
Zinc |
0.0000063 |
0.0000021 |
Naphthalene |
0.0000021 |
|
Tetrachloroethylene |
0.0000031 |
|
pH |
(2) |
(2) |
1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are cotreated with descaling or combination acid pickling wastewaters. |
2 Within the range of 6.0 to 9.0. |
[47 FR 23284, May 27, 1982, as amended at 49 FR 21035, May 17, 1984; 49 FR 24726, June 15, 1984]