7.104—Internal static pressure test.
(a) Test procedures.
(1)
Isolate and seal each segment of the intake system or exhaust system to allow pressurization.
(2)
Internally pressurize each segment of the intake system or exhaust system to four times the maximum pressure observed in each segment during the tests of § 7.100, or psig ±5 psig, whichever is less. Maintain the pressure for a minimum of 10 seconds.
(3)
Following the pressure hold, the pressure shall be removed and the pressurizing agent removed from the intake system or exhaust system.
(b) Acceptable performance.
(1)
The intake system or exhaust system, during pressurization, shall not exhibit—
(2)
Following removal of the pressurizing agent, the intake system or exhaust system shall not exhibit any—
(v)
Damaged threads of parts affecting the explosion-proof integrity of the intake system or exhaust system; or
(vi)
Permanent distortion of any planar surface of the diesel power package exceeding 0.04-inches/linear foot.