57.22222—Ventilation materials (I-A, I-B, I-C, II-A, III, V-A, and V-B mines).

All mines shall be ventilated mechanically.
(a) Main fans shall be—
(1) Installed on the surface in noncombustible housings provided with noncombustible air ducts;
(2) Except in Subcategory I-A mines, provided with an automatic signal device to give an alarm when the fan stops. The signal device shall be located so that it can be seen or heard by a person designated by the mine operator.
(b) Fan installations shall be—
(1) Offset so that the fan and its associated components are not in direct line with possible explosive forces;
(2) Equipped with explosion-doors, a weak-wall, or other equivalent devices located to relieve the pressure that would be created by an explosion underground. The area of the doors or weak-wall shall be at least equivalent to the average cross-sectional area of the airway.
(c) (1) All main fan-related electrical equipment and cables located within or exposed to the forward or reverse airstream shall be approved by MSHA under the appliable requirements of 30 CFR part 18 ;
(2) Drive belts and nonmetallic fan blades shall be constructed of static-conducting material; and
(3) Aluminum alloy fan blades shall not contain more than 0.5 percent magnesium. [Paragraph (c)(3) of this section does not apply to Subcategory I-C mines].
(d) When an internal combustion engine is used to power a main fan or as standby power, the engine shall be—
(1) Installed in a noncombustible housing;
(2) Protected from a possible fuel supply fire or explosion; and
(3) Located out of direct line with the forward and reverse airstream provided by the fan. Engine exhaust gases shall be vented to the atomsphere so that exhaust cannot contaminate mine intake air.
(e) For Subcategory I-A mines only: Main exhaust fans shall be equipped with methane monitors to give an alarm when methane in the return air reaches 0.5 percent. The alarm shall be located so that it can be seen or heard by a person designated by the mine operator.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 52 FR 41397, Oct. 27, 1987]
Main fans shall be operated continuously while ore production is in progress.
Main fans shall be—
(a) Provided with a pressure-recording system; and
(b) Inspected daily while operating if persons are underground. Certification of inspections shall be made by signature and date. Certifications and pressure recordings shall be retained for at least one year and made available to an authorized representative of the Secretary.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 52 FR 41397, Oct. 27, 1987; 60 FR 33722, June 29, 1995]
In mines ventilated by multiple main fans, each main fan installation shall be equipped with noncombustible doors. Such doors shall automatically close to prevent air reversal through the fan. The doors shall be located so that they are not in direct line with explosive forces which could come out of the mine.
(a) When there has been a main ventilation failure, such as stoppage of main fans or failure of other components of the main ventilation system, tests for methane shall be conducted in affected active workings until normal air flow has resumed.
(b) If a total failure of ventilation occurs while all persons are out of the mine and the failure lasts for more than 30 minutes, only competent persons shall be allowed underground to examine the mine or to make necessary ventilation changes. Other persons may reenter the mine after the main fans have been operational for at least 30 minutes, or after the mine atmosphere has been tested and contains less than 1.0 percent methane. Persons other than examiners shall not reenter a Subcategory II-A mine until the methane level is less than 0.5 percent.
(a) Booster fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18, and be—
(1) Provided with an automatic signal device located so that it can be seen or heard by a person designated by the mine operator to give an alarm when the fan stops or when methane reaches the following levels:
(i) 1.0 percent at the fan in Subcategory I-A, Category III, and Subcategory V-A mines; and
(ii) 0.5 percent at the fan in Subcategory II-A mines.
(2) Equipped with a device that automatically deenergizes power in affected workings should the fan stop; and
(3) Equipped with starting and stopping controls located at the fan and at another accessible remote location.
(b) Booster fan installations, except for booster fans installed in ducts, shall be—
(1) Provided with doors which open automatically when all fans in the installation stop; and
(2) Provided with an air lock when passage through the fan bulkhead is necessary.
(a) Auxiliary fans, except fans used in shops and other areas which have been so designed that methane cannot enter the airway, shall be approved by MSHA under the applicable requirements of 30 CFR part 18, and be operated so that recirculation is minimized. Auxiliary fans shall not be used to ventilate work places during the interruption of normal mine ventilatioin.
(b) Tests for methane shall be made at auxiliary fans before they are started.
Electric auxiliary fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18. Tests for methane shall be made at electric auxiliary fans before they are started. Such fans shall not be operated when air passing over or through them contains 0.5 percent or more methane.
Filters or separators shall be installed on air-lift fan systems to prevent explosive concentrations of dust from passing through the fan.
The average air velocity in the last open crosscut in pairs or sets of developing entries, or through other ventilation openings nearest the face, shall be at least 40 feet per minute. The velocity of air ventilating each face at a work place shall be at least 20 feet per minute.
Air flow across each working face shall be sufficient to carry away any accumulation of methane, smoke, fumes, and dust.
The quantity of air coursed through the last open crosscut in pairs or sets of entries, or through other ventilation openings nearest the face, shall be at least 6,000 cubic feet per minute, or 9,000 cubic feet per minute in longwall and continuous miner sections. The quantity of air across each face at a work place shall be at least 2,000 cubic feet per minute.
(a) Changes in ventilation which affect the main air current or any split thereof and which adversely affect the safety of persons in the mine shall be made only when the mine is idle.
(b) Only persons engaged in making such ventilation changes shall be permitted in the mine during changes.
(c) Power shall be deenergized in affected areas prior to making ventilation changes, except power to monitoring equipment determined by MSHA to be intrinsically safe under 30 CFR part 18. Power shall not be restored until the results of the change have been determined and a competent person has examined affected working places for methane.
Main intake and return air currents shall be coursed through separate mine openings and shall be separated throughout the mine, except—
(a) Where multiple shafts are used for ventilation and a single shaft contains a curtain wall or partition for separation of air currents. Such wall or partition shall be constructed of reinforced concrete or other noncombustible equivalent, and provided with pressure-relief devices.
(b) During development of openings to the surface—
(1) Ventilation tubing approved by MSHA in accordance with 30 CFR part 7 or previously issued a BC or VT acceptance number by the MSHA Approval and Certification Center may be used for separation of main air currents in the same opening. Flexible ventilation tubing shall not exceed 250 feet in length.
(2) Only development related to making a primary ventilation connection may be performed beyond 250 feet of the shaft.

Code of Federal Regulations

[52 FR 24941, July 1, 1987, as amended at 54 FR 30508, July 20, 1989]
The main intake and return air currents in single shafts shall be separated by ventilation tubing, curtain walls, or partitions. Ventilation tubing shall be constructed of noncombustible material. Curtain walls or partitions shall be constructed of reinforced concrete or other noncombustible equivalent, and provided with pressure-relief devices.
All seals, and those stoppings that separate main intake from main return airways, shall be of substantial construction and constructed of noncombustible materials, except that stoppings constructed of brattice materials may be used in face areas.
(a) All seals, and those stoppings that separate main intake from main return airways, shall be of substantial construction, except that stoppings constructed of brattice materials may be used in face areas.
(b) Exposed surfaces on the intake side of stoppings constructed of combustible materials or foam-type blocks shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance. Stoppings constructed to phenolic foam blocks at least 12 inches thick need not be coated for fire resistance. All foam-type blocks used for stopping construction shall be solid.
(c) Exposed surfaces on the fresh air side of seals constructed of combustible materials shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance. Foam-type blocks shall not be used for seals.
(a) Exposed surfaces on the intake side of stoppings constructed of combustible materials, except brattice, shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance.
(b) Seals shall be of substantial construction. Exposed surfaces on the fresh air side of seals constructed of combustible materials shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance. Foam-type blocks shall not be used for seals.
Air that has passed by or through unsealed abandoned or unsealed inactive areas and contains 0.25 percent or more methane shall—
(a) Be coursed directly to a return airway;
(b) Be tested daily for methane by a competent person; and
(c) Not be used to ventilate work places.
Overcasts and undercasts shall be—
(a) Of substantial construction;
(b) (1) Constructed of noncombustible materials; or
(2) Where constructed of combustible materials, the outside surfaces shall be coated with at least one inch of construction plaster containing perlite and gypsum; at least one inch of expanded vermiculite, Portland cement and limestone; or other coatings with equivalent fire resistance;
(c) Kept clear of obstructions.
Brattice cloth and ventilation tubing shall be approved by MSHA in accordance with 30 CFR part 7, or shall bear a BC or VT acceptance number issued by the MSHA Approval and Certification Center.

Code of Federal Regulations

[54 FR 30508, July 20, 1989]
A means of ventilating faces shall be provided before workings are abandoned in unsealed areas, unless crosscuts are provided within 30 feet of the face.
Battery charging stations, compressor stations, pump stations, and transformer stations shall be installed in intake air at locations which are sufficiently ventilated to prevent the accumulation of methane.
Battery charging stations, compressor stations, and electrical substations shall not be installed underground or within 50 feet of a mine opening.
Tests for methane shall be conducted in the mine atmosphere by a competent person—
(a) At least once each shift prior to starting work in each face and raise; and
(b) Upon initial release of gas into the mine atmosphere from boreholes.
(a) Methane monitoring devices and portable, battery-powered, self-contained devices used for measuring methane, other gases, and contaminants in mine air shall be approved by MSHA under the applicable requirements of 30 CFR parts 18, 21, 22, 23, 27, and 29. Such devices shall be maintained in accordance with manufacturers' instructions, or an equivalent maintenance and calibration procedure.
(b) (1) Flame safety lamps shall not be used to test for methane except as supplementary devices.
(2) Flame safety lamps shall not be used in Subcategory I-C mines.
(c) (1) If electrically powered, remote sensing devices are used, that portion of the instrument located in return air or other places where combustible gases may be present shall be approved by MSHA under the applicable requirements of 30 CFR parts 18, 22, 23, 27, and 29.
(2) If air samples are delivered to remote analytical devices through sampling tubes, such tubes shall be provided with in-line flame arrestors. Pumping equipment and analytical instruments shall be located in intake air.
(a) Preshift examinations shall be conducted within three hours prior to the start of the shift for which the examination is being made.
(b) Prior to the beginning of a shift following an idle shift, a competent person shall test the mine atmosphere for methane at all work places before persons other than examiners enter the mine.
(c) When one shift immediately follows another, a competent person shall test the mine atmosphere at each active working face for methane before work is started on that shift.
(d) A competent person shall test the mine atmosphere at each face blasted before work is started.
(e) Except in Subcategory I-C or Category III mines, vehicles used for transportation when examining the mine shall be approved by MSHA under the applicable requirements of 30 CFR parts 18 through 36.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 53 FR 9615, Mar. 24, 1988]
(a) The mine atmosphere shall be tested for methane and carbon monoxide at least once every seven days by a competent person or an atmospheric monitoring system, or a combination of the two. Such testing shall be done at the following locations:
(1) The return of each split where it enters the main return;
(2) Adjacent to retreat areas, if accessible;
(3) At least one seal of each sealed area, if accessible;
(4) Main returns;
(5) At least one entry of each intake and return;
(6) Idle workings; and
(7) Return air from unsealed abandoned workings.
(b) The volume of air (velocity in Subcategory I-A mines) shall be measured at least once every seven days by a competent person. Such measurement shall be done at the following locations:
(1) Entering main intakes;
(2) Leaving main returns;
(3) Entering each main split;
(4) Returning from each main split; and
(5) In the last open crosscuts or other ventilation openings nearest the active faces where the air enters the return.
(c) Where such examinations disclose hazardous conditions, affected persons shall be informed and corrective action shall be taken.
(d) Certification of examinations shall be made by signature and date. Certifications shall be retained for at least one year and made available to authorized representatives of the Secretary.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 52 FR 41397, Oct. 27, 1987]
(a) The mine atmosphere shall be tested for methane at least once every seven days by a competent person or an atmospheric monitoring system, or a combination of the two. Such testing shall be done at the following locations:
(1) Active mining faces and benches;
(2) Main returns;
(3) Returns from idle workings;
(4) Returns from abandoned workings; and
(5) Seals.
(b) Where such examinations disclose hazardous conditions, affected persons shall be informed and corrective action shall be taken.
(c) Certification of examinations shall be made by signature and date. Certifications shall be kept for at least one year and made available to authorized representatives of the Secretary.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 52 FR 41397, Oct. 27, 1987; 60 FR 33723, June 29, 1995]
If methane reaches 0.25 percent in the mine atmosphere, changes shall be made to improve ventilation, and MSHA shall be notified immediately.
If methane reaches 0.5 percent in the mine atmosphere, ventilation changes shall be made to reduce the level of methane. Until methane is reduced to less than 0.5 percent, electrical power shall be deenergized in affected areas, except power to monitoring equipment determined by MSHA to be intrinsically safe under 30 CFR part 18. Diesel equipment shall be shut off or immediately removed from the area and no other work shall be permitted in affected areas.

Code of Federal Regulations

[52 FR 24941, July 1, 1987; 52 FR 27903, July 24, 1987]
If methane reaches 0.5 percent in the mine atmosphere, ventilation changes shall be made to reduce the level of methane. Until methane is reduced to less than 0.5 percent, no other work shall be permitted in affected areas.

Code of Federal Regulations

[52 FR 24941, July 1, 1987; 52 FR 27903, July 24, 1987]
(a) If methane reaches 1.0 percent in the mine atmosphere, ventilation changes shall be made to reduce the methane. Until such changes are achieved—
(1) All persons other than competent persons necessary to make the ventilation changes shall be withdrawn from affected areas;
(2) Electrical power shall be deenergized in affected areas, except power to monitoring equipment determined by MSHA to be intrinsically safe under 30 CFR part 18; and
(3) Diesel equipment shall be shut off or immediately removed from the area.
(b) If methane reaches 1.0 percent at a main exhaust fan, electrical power underground shall be deenergized, except power to monitoring equipment determined by MSHA to be intrinsically safe under 30 CFR part 18, and all persons shall be withdrawn from the mine.
(c) If methane reaches 1.0 percent at a work place and there has been a failure of the main ventilation system, all persons shall be withdrawn from the mine.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 53 FR 9615, Mar. 24, 1988]
(a) If methane reaches 1.0 percent in the mine atmoshpere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until methane is reduced to less than 0.5 percent.
(b) If methane reaches 1.0 percent at a work place and there has been a failure of the main ventilation system, all persons shall be withdrawn from the mine.
If methane reaches 1.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until methane is reduced to less than 0.5 percent.
If methane reaches 2.0 percent in bleeder systems at the point where a bleeder split enters a main return split, mining shall not be permitted on ventilation splits affected by the bleeder system. If methane has not been reduced to less than 2.0 percent within 30 minutes, or if methane levels reach 2.5 percent, all persons other than competent persons necessary to take corrective action shall be withdrawn from affected areas.
If methane reaches 2.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from the mine until methane is reduced to less than 0.5 percent.
If methane reaches 2.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from the mine until methane is reduced to less than 0.5 percent. MSHA shall be notified immediately.

Code of Federal Regulations

[52 FR, 24941, July 1, 1987, as amended at 52 FR 41397, Oct. 27, 1987; 60 FR 33723, June 29, 1995]
If methane reaches 2.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until methane is reduced to less than 1.0 percent.

Code of Federal Regulations

[52 FR 24941, July 1, 1987; 52 FR 27903, July 24, 1987]
(a) Boreholes shall be drilled at least 25 feet in advance of a face whenever the work place is within—
(1) 50 feet of a surveyed abandoned mine or abandoned workings which cannot be inspected; or
(2) 200 feet of an unsurveyed abandoned mine or abandoned workings which cannot be inspected.
(b) Boreholes shall be drilled in such a manner to insure that the advancing face will not accidently break into an abandoned mine or abandoned working.