250.617—What are my BOP inspection and maintenance requirements?

(a) BOP inspections. (1) You must inspect your BOP system to ensure that the equipment functions properly. The BOP inspections must meet or exceed the provisions of Sections 17.10 and 18.10, Inspections, described in API RP 53, Recommended Practices for Blowout Prevention Equipment Systems for Drilling Wells (incorporated by reference as specified in § 250.198 ). You must document the procedures used, record the results, and make them available to BOEMRE upon request. You must maintain your records on the rig for 2 years or from the date of your last major inspection, whichever is longer.
(2) You must visually inspect your BOP system and marine riser at least once each day if weather and sea conditions permit. You may use television cameras to inspect this equipment. The District Manager may approve alternate methods and frequencies to inspect a marine riser.
(b) BOP maintenance. You must maintain your BOP system to ensure that the equipment functions properly. The BOP maintenance must meet or exceed the provisions of Sections 17.11 and 18.11, Maintenance; and Sections 17.12 and 18.12, Quality Management, described in API RP 53, Recommended Practices for Blowout Prevention Equipment Systems for Drilling Wells (incorporated by reference as specified in § 250.198 ). You must document the procedures used, record the results, and make them available to BOEMRE upon request. You must maintain your records on the rig for 2 years or from the date of your last major inspection, whichever is longer.

Code of Federal Regulations

[75 FR 63376, Oct. 14, 2010]