18.60—Detailed inspection of components.
An inspection of each electrical component shall include the following:
(a)
A detailed check of parts against the drawings submitted by the applicant to determine that: (1) The parts and drawings coincide; and (2) the minimum requirements stated in this part have been met with respect to materials, dimensions, configuration, workmanship, and adequacy of drawings and specifications.
(e)
Examination for adequacy of electrical insulation and clearances between live parts and between live parts and the enclosure.
(h)
Examination for adequacy of fastenings, including size, spacing, security, and possibility of bottoming.