1917.157—Battery charging and changing.
(f)
When a jumper battery is connected to a battery in a vehicle, the ground lead shall connect to ground away from the vehicle's battery. Ignition, lights and accessories on the vehicle shall be turned off before connections are made.
(i)
Facilities for flushing the eyes, body and work area with water shall be provided wherever electrolyte is handled, except that this requirement does not apply when employees are only checking battery electrolyte levels or adding water.
(k)
Battery handling equipment which could contact battery terminals or cell connectors shall be insulated or otherwise protected.
(o)
Installed batteries shall be secured to avoid physical or electrical contact with compartment walls or components.