29.1181—Designated fire zones: regions included.
(3)
Any complete powerplant compartment in which there is no isolation between the engine power section and the engine accessory section, for reciprocating engines;
(7)
The combustor, turbine, and tailpipe sections of turbine engine installations except sections that do not contain lines and components carrying flammable fluids or gases and are isolated from the designated fire zone prescribed in paragraph (a)(6) of this section by a firewall that meets § 29.1191.