23.1395—Maximum intensities in overlapping beams of position lights.
No position light intensity may exceed the applicable values in the following equal or exceed the applicable values in § 23.1389(b)(3) :
Overlaps | Maximum intensity | |
---|---|---|
Area A (candles) | Area B (candles) | |
Green in dihedral angle L | 10 | 1 |
Red in dihedral angle R | 10 | 1 |
Green in dihedral angle A | 5 | 1 |
Red in dihedral angle A | 5 | 1 |
Rear white in dihedral angle L | 5 | 1 |
Rear white in dihedral angle R | 5 | 1 |
Where—
(a)
Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and
(b)
Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.