23.1393—Minimum intensities in any vertical plane of position lights.
Each position light intensity must equal or exceed the applicable values in the following table:
| Angle above or below the horizontal plane | Intensity, l |
|---|---|
| 0° | 1.00 |
| 0° to 5° | 0.90 |
| 5° to 10° | 0.80 |
| 10° to 15° | 0.70 |
| 15° to 20° | 0.50 |
| 20° to 30° | 0.30 |
| 30° to 40° | 0.10 |
| 40° to 90° | 0.05 |