23.1195—Fire extinguishing systems.
(a)
For commuter category airplanes, fire extinguishing systems must be installed and compliance shown with the following:
(1)
Except for combustor, turbine, and tailpipe sections of turbine-engine installations that contain lines or components carrying flammable fluids or gases for which a fire originating in these sections is shown to be controllable, a fire extinguisher system must serve each engine compartment;
(2)
The fire extinguishing system, the quantity of the extinguishing agent, the rate of discharge, and the discharge distribution must be adequate to extinguish fires. An individual “one shot” system may be used.
(3)
The fire extinguishing system for a nacelle must be able to simultaneously protect each compartment of the nacelle for which protection is provided.
(b)
If an auxiliary power unit is installed in any airplane certificated to this part, that auxiliary power unit compartment must be served by a fire extinguishing system meeting the requirements of paragraph (a)(2) of this section.