431.136—Energy conservation standards and their effective dates.

Each automatic commercial ice maker that produces cube type ice with capacities between 50 and 2500 pounds per 24-hour period when tested according to the test standard established in accordance with section 343 of EPCA (42 U.S.C. 6314) and is manufactured on or after January 1, 2010, shall meet the following standard levels:
Equipment type Type of cooling Harvest rate(lbs ice/24 hours) Maximum energy use(kWh/100 lbs ice) Maximum condenser water use *(gal/100 lbs ice)
Ice Making Head Water <500 7.80-0.0055H 200-0.022H.
Ice Making Head Water ≥500 and <1436 5.58-0.0011H 200-0.022H.
Ice Making Head Water ≥1436 4.0 200-0.022H.
Ice Making Head Air <450 10.26-0.0086H Not applicable.
Ice Making Head Air ≥450 6.89-0.0011H Not applicable.
Remote Condensing (but not remote compressor) Air <1000 8.85-0.0038H Not applicable.
Remote Condensing (but not remote compressor) Air ≥1000 5.1 Not applicable.
Remote Condensing and Remote Compressor Air <934 8.85-0.0038H Not applicable.
Remote Condensing and Remote Compressor Air ≥934 5.3 Not applicable.
Self Contained Water <200 11. 40-0.019H 191-0.0315H.
Self Contained Water ≥200 7.6 191-0.0315H.
Self Contained Air <175 18.0-0.0469H Not applicable.
Self Contained Air ≥175 9.8 Not applicable.
HHarvest rate in pounds per 24 hours.
* Water use is for the condenser only and does not include potable water used to make ice.

Code of Federal Regulations

[70 FR 60415, Oct. 18, 2005; 70 FR 61698, Oct. 25, 2005]