34.45—Operating and emergency procedures.
(1)
Appropriate handling and use of licensed sealed sources and radiographic exposure devices so that no person is likely to be exposed to radiation doses in excess of the limits established in 10 CFR part 20 of this chapter “Standards for Protection Against Radiation”;
(4)
Methods and occasions for locking and securing radiographic exposure devices, transport and storage containers and sealed sources;
(6)
Transporting sealed sources to field locations, including packing of radiographic exposure devices and storage containers in the vehicles, placarding of vehicles when needed, and control of the sealed sources during transportation (refer to 49 CFR parts 171-173 );
(7)
The inspection, maintenance, and operability checks of radiographic exposure devices, survey instruments, transport containers, and storage containers;
(8)
Steps that must be taken immediately by radiography personnel in the event a pocket dosimeter is found to be off-scale or an alarm ratemeter alarms unexpectedly.
(9)
The procedure(s) for identifying and reporting defects and noncompliance, as required by 10 CFR part 21 of this chapter ;
(b)
The licensee shall maintain copies of current operating and emergency procedures in accordance with §§ 34.81 and 34.89.